Tuesday, December 7, 2010

Kate´s Playground 2009 December

Smart Pen or scam Beware of

The scam smart pen or scratch free and 'just awesome, deal in a transparent pen as if it were magic, however, if the smear and' deep, you can not 'do is touch up the paint brush or paint.
The scam is to show that the pen cover the smears of any color is the paint, but instead they go back the image of the smear, I am attaching the video so you understand better.
few months ago, ' watching TV, I noticed the video below on the magic pen and I immediately contacted both the paint factory of trust and the other five I work with angry because we had not introduced this new product as in our company are always welcome news.

Just the other day a customer came to us asking us all worried help because he could not run the marker just bought to repair the scratches on the body, and it was just the smart pen of advertising. We immediately started to look to try to understand why this came out clear liquid that gave no effect on the smear machine of our customers, and we understand where's the catch doing some tests on old pieces of bodywork.

The scam is the fact that if the smear is very light, the pen is able to cover it: But 'if and' then it can be so light to shine without significant cost, in fact, you can do it by yourself using a bit 'of compound. However, if the smear is less than half a millimeter below the glass of the car (as they see in advertising), there is little 'more to do nothing but tinkering with the brush or painting, because this "fantastic" fails to place the product smears deep.

Moral of the story: the customer who 'came to him for help now finds itself with a useless product and was criticized for being so' naive as to have fallen into this scam.



Ps Take a enamel for nails will make 'the same function !






scam smart pen

Friday, November 5, 2010

Sandpaper For Pedicure

How much does the environment proof of efficacy ...

wish to submit a reflection. The UNI EN 858-1 paragraph 8.3.3.1.4 describes how the test should be conducted for the effectiveness of prefabricated oil separators. The test is introduced that provides a flow of water contaminated with a defined quantity of oil to the system, equal to what extent this can be covered for the time necessary to change 4 times the volume of the tank. After this time you run the output of the plant and five samples for chemical analysis is undertaken to evaluate the purification performance. Let's take a practical example to understand the volumes of water and oil are put into play. Suppose we want to test a system of 50 lt / sec, which, among other things, represents a rather small size, whereas the rule exempts from testing only facilities capable of handling a range greater than 150 l / sec and castings . The scope then be placed in our facility is 50 lt / sec for about 21 minutes, since the latter calculated from the volume of our tub and the multiplication factor 4. The volume of water that is conivolto in evidence in this period is therefore equal to 64,000 liters that is 64 cubic . These 64 mc are contaminated and then polluted with 320 liters of oil and at best that the system has the performance to be classified in Class I, the concentration of oil at the drain is still a 5 mg / liter to 0.4 liters of oil still which continue to be "inseparable" from the water mass. If then the system falls into class II, and then requires a value to the discharge of 100 mg / lt the amount of residual oil inseparate will be about 7 liters. Do not think so a little 'paradoxical that in order to test the performance of a system should be such high volumes pollute the precious liquid that we all rush to protect??
http://www.boergroup.it/

Friday, October 29, 2010

Ratchet And Clank Blueprints For The Rhino V

Grease separators super serviced!

UNI EN 1825-1 regulates the design and construction of the separation of fat to be installed for the discharges from kitchens, canteens and productive activities such as slaughterhouses. E 'compulsory in Italy for some years. The 1825-2 is not mandatory but provides valuable information on dimensiomento and volumes to be considered, provided that the efficiency of the system and its nominal size (in practice the extent that it is capable of treating the plant) must be tested using the test described in detail in accordance with 1825-1. In paragraph 8 of the 1825-2
we talk then listen, listen to maintenance and ... ... recommended cleaning frequencies are monthly or preferably every two weeks !!!!! So
our conclusion is:
well use the sizing criteria spelled out in 1825-2, among other things written really well, but beware of over-design, with a fair dose of common sense, a little 'because the system is in Italy unthinkable recommend purging of condensing two times a month!
http://www.boergroup.it/

Wednesday, October 27, 2010

Usedtrailers In N.ireland

valve stopper: there really are benefits?

Pros and cons of one of the most popular accessories for oil extraction plants in continuous
The rule governing the design and realization of the plants oil extraction, the UNI EN 858-1 compulsory in Italy for some years now, provides the point 6.5.3 and 6.5.4, respectively, to the point that there is the presence of the shutoff valve and safety of electronic detection oils. In the various business proposals and chapters, has given high preference in recent years with respect to the valve closing detecting equipment oils, without justification.

What is the safety shut-off valve?
valve safety lock is a mechanical device that is placed in the inlet pipe or outlet of the separator and its operation is usually controlled by a float. The stratification of the oil floating on the surface is set on density of water drops below the layer of oil and a device which blocks the pipe. The purpose of this valve is to prevent the pumping of oil to the receiving body, however, not without cause serious trouble.

understand the consequences of this closure is essential to choose whether to apply the valve in the system. During the various rainfall accumulates in the oil separator and during one of these at the end of it, the float triggers the closure by blocking the pipe.

If the valve is positioned in the inlet pipe, not during the next rainstorm allow the flow of waste by raising the water level upstream of the piping, with the risk that the water comes out of the parking area drains or roads, flooding.
If the valve is placed in the pipe out, levels in the plant will rise and oil and water can leak out from manhole covers in addition to regurgitate in the pipes upstream.

Therefore the ns. opinion is that the safety shut-off valve can cause more trouble than good, and we prefer to place the plant in its place the electronic device for detecting oils, electrical equipment also powered by solar panels if necessary, can be detected by measuring the electrical conductivity of the laminated oil level in the tank and send a signal to schedule your time maintaining the system. The equipment can be calibrated to the desired level of accumulation in order to ensure maximum efficiency of the purification system.